Outdoor Lighting Management Plan: A Dark Sky Field Guide
Dark Sky Parks and Recreation

Outdoor Lighting Management Plan: How Parks, Campuses, and Towns Keep the Night Dark

By Access Fixtures Lighting Specialists·Dark Sky Parks and Recreation·November 2026

A lighting management plan is the written rulebook for every outdoor light on a property. It says which fixtures are allowed, how they are shielded, what color they emit, when they turn off, and who checks. DarkSky International expects one from every International Dark Sky Place. Parks, campuses, resorts, and towns that want to protect the night sky need one too, certified or not. On November 11, 2026, Fiordland National Park in New Zealand became the world's third-largest International Dark Sky Park, covering 12,607 square kilometres, and the Southland Tribune reported that a Lighting Management Plan will guide the park's ongoing outdoor lighting (Southland Tribune, November 11, 2026). The fixtures get the attention. The plan keeps the result.

What Is a Lighting Management Plan?

Golden Gate Canyon State Park night sky with shielded warm lighting

A lighting management plan (LMP) is a policy document that governs all existing and future outdoor lighting on a site. It turns dark sky principles into enforceable rules that staff, contractors, and future managers can follow. Without a plan, a dark sky friendly retrofit erodes one replacement fixture at a time.

A strong plan does three jobs:

  • Sets the rules. Shielding, color, light levels, curfews, and controls.
  • Documents the starting point. A lighting inventory of every existing fixture.
  • Assigns responsibility. Who approves new lighting, who maintains it, and how changes are recorded.

What DarkSky International's Sample Plan Sets

DarkSky International publishes a Sample Lighting Management Plan for International Dark Sky Parks, Reserves, and Sanctuaries (rev. 11/6/2017). It says a plan with its minimum provisions is consistent with program requirements. Its core provisions:

  • Default to darkness. New lighting is added only where the manager determines a public safety hazard exists that only outdoor light can mitigate.
  • Full shielding. Fixtures with lamps of 500 initial lamp lumens or more are fully shielded. DarkSky encourages, but does not require, full shielding of all lighting.
  • Color. The sample says no lamp may exceed a correlated color temperature of 3000 Kelvins, and the park prefers amber and similar colors.
  • Light levels. It sets maximum illuminance values by area, such as building entries, parking lots, and signage, and states that trails should not be lit.
  • Curfew. Outdoor lighting is extinguished from a set hour (the sample suggests 10 PM) until one hour before sunrise, unless visitor, staff, or traffic needs dictate otherwise.
  • Adaptive controls. Timers, motion sensors, and dimming are used to the greatest practical extent possible.
  • Signs, temporary, and visitor lighting. Each is limited, and visitor lighting goes off by the park curfew.

Each certified site adapts these provisions to its own conditions. Confirm the current program guidelines with DarkSky International before you submit an application.

How to Build a Lighting Management Plan in Five Steps

  1. Inventory every fixture. Record location, type, wattage, color temperature, shielding, and controls. Photograph each one.
  2. Classify each area by need. Separate life-safety areas (entries, parking, steps) from areas that need no light at all.
  3. Set the rules. Adopt shielding, color, light level, curfew, and control provisions. Start from the DarkSky sample and your local ordinance.
  4. Plan the retrofit. List the fixtures that fail the rules, then replace, re-aim, shield, or remove them. A photometric study shows where the new light lands before you buy.
  5. Assign ownership and review. Name who approves new lighting, how replacements are specified, and when the plan is reviewed.
Five steps to build an outdoor lighting management plan Five boxes in order: 1 Inventory every fixture, 2 Classify each area by need, 3 Set the rules for shielding, color, levels, and curfew, 4 Plan the retrofit, 5 Assign an owner and review. Five steps to a lighting management plan 1. Inventory every fixture 2. Classify each area by need 3. Set the rules shielding, color, levels, curfew 4. Plan the retrofit 5. Assign owner and review A photometric study checks step 4 before you buy any fixture.
Illustration. The five steps in order. A photometric study checks the retrofit plan before you buy.

The order of work inside a plan follows our light pollution mitigation hierarchy: remove, confine and dim, limit hours, then adjust spectrum.

Light Levels: Use the Standard, Not a Guess

Dark sky friendly does not mean dark everywhere. Parking areas still need safe light. For parking lots, Access Fixtures designs to the IES research recommendation of about 0.2 footcandle (2 lux) average pavement illuminance (per IES RES-2-18 recommendation, Section 9.0). Codes, ordinances, and the authority having jurisdiction supersede IES recommendations, and a certified park's own plan may set lower limits.

Who Needs a Lighting Management Plan?

  • National, state, and county parks seeking or keeping International Dark Sky Park status.
  • Gateway towns and counties near dark sky places, where astrotourism depends on lighting beyond the park boundary.
  • Resorts and lodging pursuing DarkSky certification. See our guide to DarkSky Approved Resorts.
  • Campuses, HOAs, and federal sites that want consistent, dark sky friendly lighting across many buildings and contractors.

Fixtures That Fit a Lighting Management Plan

The plan sets the rules. The fixtures have to meet them for years. The APTA 590nm amber LED area and flood light is built for long-term dark sky plans:

  • 590nm amber LEDs, matching the amber preference in DarkSky's sample plan.
  • IP66 and IK10 rated.
  • Controls built in: an optional photocell and a programmable microwave motion sensor that can control multiple APTAs.
APTA 590nm amber LED area light at evening
APTA 590nm amber LED area light

For more park applications, see Dark Skies National Parks.

Sources: Southland Tribune, November 11, 2026; DarkSky International, Sample Lighting Management Plan (rev. 11/6/2017); IES RES-2-18.

Access Fixtures Solutions

APTA 590nm Amber Area Light

IP66 and IK10, with an optional photocell and microwave motion sensor. See the APTA page.

See the APTA Page →

Bollard Pathway Lighting

Low-height bollards for paths and visitor areas.

Shop Bollard Lights →

Wildlife Friendly LED Lighting

Amber and shielded wildlife friendly fixtures.

Explore Wildlife Friendly Lighting →

Photometric Studies

Model your plan's light levels before you buy.

Request a Photometric Study →

Frequently Asked Questions

What is an outdoor lighting management plan?

An outdoor lighting management plan is a written policy that governs every outdoor light on a property. It sets rules for shielding, color temperature, light levels, curfews, and controls, and it names who approves and maintains lighting.

Does DarkSky International require a lighting management plan?

Yes. DarkSky International expects International Dark Sky Places to manage outdoor lighting under a plan. It publishes a sample plan for parks, reserves, and sanctuaries, and states that a plan with its minimum provisions is consistent with program requirements.

What color temperature does a dark sky lighting management plan allow?

DarkSky International's sample plan states that no lamp may exceed 3000 Kelvins correlated color temperature. It also states a preference for amber and similar colors.

Which fixtures must be fully shielded?

In DarkSky International's sample plan, fixtures with lamps equal to or greater than 500 initial lamp lumens must be fully shielded. DarkSky encourages full shielding of all fixtures.

When should outdoor lights turn off under a lighting management plan?

The sample plan extinguishes outdoor lighting from a set curfew hour, suggested as 10 PM, until one hour before sunrise. Exceptions apply where visitor, staff, or traffic needs require light.

What is a lighting inventory?

A lighting inventory is a record of every existing outdoor fixture: location, type, wattage, color temperature, shielding, and controls. It is the baseline the lighting management plan measures against.

Does a site need to be certified to use a lighting management plan?

No. Any park, campus, town, resort, or HOA can adopt a lighting management plan. Certification is one reason to write one; consistent, dark sky friendly lighting is the other.

How does a photometric study support a lighting management plan?

A photometric study models where light lands before fixtures are bought. It shows whether the design meets the plan's light levels and keeps light off the sky and neighboring property.

Start Your Lighting Management Plan

The plan protects the night. The fixtures prove the plan works. An Access Fixtures lighting specialist can review your inventory, match fixtures to your plan, and order a photometric study from a lighting engineer. Call 800-468-9925 or request a photometric study online.

800-468-9925